MiniAir6 / 64 - probe anemometer
|
The self-contained anemometer probe MiniAir6/64 measures the velocity of gaseous media, directly giving out a linear current signal. The MiniAir64 like other MiniAir models features the unique Snap Head on types Micro and Mini, providing on-site serviceability, thus making it ideal for continual measuring.
In anemometry, the accuracy achieved by a vane probe is acknowledged to be unmatched.
The vane rotation is closely linear to flow velocity and is unaffected by pressure, temperature, density and humidity.
Typical applications are:
Air conditioning and heating engineering
Clean room and process management
Enviroment
|
Types:
| MiniAir6/64 |
Micro |
20 m/s |
| MiniAir6/64 |
Micro |
40 m/s |
| MiniWater6/64 |
Micro |
5 m/s |
|
|
|
| MiniAir6/64 |
Mini |
20 m/s |
| MiniAir6/64 |
Mini |
40 m/s |
| MiniWater6/64 |
Mini |
5 m/s |
|
|
|
| MiniAir6/64 |
Macro |
20 m/s |
|
 |
|
|
|
|
|
|
 |
MiniAir2 and MiniAir 64 are also available with Ex-Certificate. |
|
| Technical specifications MiniAir6 and 64: |
| Air probe: |
MiniAir 6 Micro |
MiniAir 6 Mini |
MiniAir6 Macro |
| Effective range |
0,5 - 20 m/s |
0,3 - 20 m/s |
0,15 - 20 m/s |
| or |
0,7 - 40 m/s |
0,5 - 40 m/s |
|
| Accuracy |
± 1,0% fs. plus
± 3,0% rdg. |
± 1,0% fs. plus
± 3,0% rdg. |
± 1,0% fs. plus
± 3,0% rdg. |
| Operating temp. |
-10 to +80°C |
-10 to +80°C |
-10 to +80°C |
| Supply (external) |
6,5 - 26 V DC |
6,5 - 26 V DC |
6,5 - 26 V DC |
| Output |
0 - 2,0 V |
0 - 2,0 V |
0 - 2,0 V |
| Maximum load |
>10 kOhm |
>10 kOhm |
>10 kOhm |
| Head dimensions |
ø 11 x 15 mm |
ø
22 x 28 mm |
ø 80 x 70 mm |
| Probe length |
165 mm |
175 mm |
225 mm |
| Specifications subject to change without further notice. |
|
|
| Water probe: |
MiniAir 6 Micro |
MiniAir Water 6 Mini |
| Effective range |
0,04 - 5 m/s |
0,02 - 5 m/s |
| Accuracy |
±4% fs. plus
± 3% rdg. |
± 4% fs. plus
± 3% rdg. |
| Operating temp. |
0 to +70°C |
0 to +70°C |
| Supply (external) |
6,5 - 26 V DC |
6,5 - 26 V DC |
| Output |
0 - 1,0 V |
0 - 1,0 V |
| Maximum load |
>10 kOhm |
>10 kOhm |
| Head dimensions |
ø 11 x 15 mm |
ø 22 x 28 mm |
| Probe length |
165 mm |
175 mm |
|
Specifications subject to change without further notice.
|
| Air probe: |
MiniAir64 Micro |
MiniAir64 Mini |
MiniAir64 Macro |
| Effective range |
0,5 - 20 m/s |
0,3 - 20 m/s |
0,15 - 20 m/s |
| or |
0,7 - 40 m/s |
0,5 - 40 m/s |
|
- Accuracy
|
- ± 1,0% fs. plus
± 3,0% rdg.
|
- ± 0,5% fs. plus
± 1,5% rdg.
|
- ± 0,5% fs. plus
± 1,5% rdg.
|
| Operating temp. |
-10 to +80°C |
-10 to +80°C |
-10 to +80°C |
- Supply (external)
|
- 9 - 24 V DC
(depending on the used resistance)
|
- 9 - 24 V DC
(depending on the used resistance)
|
- 9 - 24 V DC
(depending on the used resistance)
|
- Output
|
- 4 - 20 mA
- 2-wire
|
- 4 - 20 mA
- 2-wire
|
- 4 - 20 mA
- 2-wire
|
| Head dimensions |
ø 11 x 15 mm |
ø 22 x 28 mm |
ø 80 x 70 mm |
| Probe dimensions |
165 mm |
175 mm |
225 mm |
|
Specifications subject to change without further notice.
|
| Water probe: |
MiniWater 64 Micro |
MiniWater 64 Mini |
| Effective range |
0,04 - 5 m/s |
0,02 - 5 m/s |
| Accuracy |
± 4% fs. plus
± 3% rdg. |
± 2% fs. plus
± 1,5% rdg. |
| Operating temp. |
0 to +70°C |
0 to +70°C |
| Supply (external) |
- 9 - 24 V DC
(depending on the used resistance)
|
- 9 - 24 V DC
(depending on the used resistance)
|
| Output |
- 4 - 12 mA
- 2-wire
|
- 4 - 12 mA
- 2-wire
|
| Head dimensions |
ø 11 x 15 mm |
ø 22 x 28 mm |
| Probe dimensions |
165 mm |
175 mm |
|
Specifications subject to change without further notice.
|
|
|
|